MPS9335C 10-1200KVA With Switch Cabinet Modular UPS Systems

MPS9335C 10-1200KVA With Switch Cabinet Modular UPS Systems
Category:

MPS9335C 10-1200KVA modular ups systems Application:

Application IDC(Internet Data Center), computing center, ISP (Internet Service Provider ),Telecom,Finance bank and securities, Tax, hospital system, industrial automation, precision equipment, etc.

 

MPS9335C 10-1200KVA modular ups systems Features:

1.Superior energy saving and environment-friendly: Efficiency > 96% at 50%-75% rated load, and > 95% at 25% rated load; Input PF > 0.99,input THDi<3%.
2.Superior capability of powering load: Output PF is 0.9 or 1, no need of power deration with load of leading or lagging PF.
3.Easy-to-install: Top or bottom cabling, no need of input cabling cabinet.
4.Easy-to-maintain: Full front access, UPS, failed part can be replaced shortly.
5.Easy-to-modify: The number of battery cells can be configured flexibly, so the original batteries can be used when modifying the legacy system; moreover, the battery cell can be replaced in time when it fails without interrupting the normal operation of modular ups systems.
6.6-inch extra large LCD that can display 13 language (Chinese ,English ,Russian, French ,Spanlish and so on).
7.Provide large LCD touch screen (optional).
8.Each UPS modules provide 4.5KW charge capacity. equivalent to 10 to 12A.
9.On-Line Double Conversion, fully isolating the influences of power grid pollution and power failure from utility power supply and diesel generator to load.
10.Advanced DSP full digital control technologies realize higher system stability, online capacity expansion and maintenance.
11.Advanced distributed active parallel technology realizes parallel operation of 4 UPS units and online capacity expansion without centralized bypass cabinet.
12.Digital load sharing technology features extra low cross current and extreme high system reliability in parallel operation.
13.Adaptive to severe power grid environment due to extra wide input voltage and frequency ranges.
14.Extra strong capability to withstand output overload and short circuit, ensuring the system stability and system safety at limit conditions.
15.Intelligent battery management maintains battery automatically to prolong the battery life.
16.Efficient heat dissipation and effective protection under severe environment due to its independent layer-sealed ventilation channel and redundant fan design, as well as the paint-protected circuit boards and built-in dust filter.
17.Applicable voltage south America.

 

MPS9335C 10-1200KVA modular ups systems  technical specifications:

Model MPS9335 10-1200KVA
Capacity 10-1200KVA
Main input
Input voltage  380V/400V/415AC(Optional South America 208v)
Input Frequency Range  50/60Hz
Power Factor Full load>0.99 ,Half load >0. 98
THDi  THDi <3%
Input power soft-start fantion 5-30s settable
Input Voltage Ranges 228V-476V-20%- +25% Full load linear derating at -25% – -40%; can take 70% load at -40%
Frequency Range 40-70Hz
Battery
Battery Voltage  ±240VDC(Default),12V Battery30-40pcs can be choose
Charge Voltage accuracy ± 1%
Bypass
Bypass Input voltage 380/400/415VAC 3-phase 4-wire
Voltage Ranges Default value is -20%-+15%, -40%, -30%, -10% – +10%, other ranges can be set viasoftware
Overload Capacity  150%,long term operation,150%<load<180%,more than 1 hour ,load>1000% 100ms
Output
Inverter Output Voltage 380/400/415VAC 3-phase 4-wire
Voltage Accuracy  ± 0.5%(balanced load), ± 1% (unbalanced load)
THDV  THDV<1%(linear load),THDV<3%(nonlinear load)
Power Factor  1
Three Phase Angle accuracy  120°c ± 0.5°c
Current Crest Ratio  3:1
Overload Capacity  110%1h,125%10mins,150%1mins,>150%200ms
Transfer Time 0ms,15ms(ECO Mode)
System
Frequency 50Hz/60Hz (Settable)
Mains synchronization range ±2Hz(Default value) adjustable with step of 0.5Hz within range of +/- 0.5Hz – 3Hz
Protection Level  IP20
Communication Ports  RS232,RS485,dry contact,SNMP card,EPO,generator port
System efficiency > 96% at load above 50%, >95% at load above 25%
Operation Temperature 0-40 °c
Storage Temperature -25 °c -70 °c (without battery)
Humidity 0-95%(no-condensing)
Noise(dB) 55-62dB,Adjusted with load
Weight 5 module cabinet module :RMS050/10, RMS100/20, RMS150/30 150KG
10 module cabinet module :RMS100/10, RMS200/20, RMS300/30 180KG
 module :PM10 10KVA power module :28KG
 module :PM20 20KVA power module :30KG
 module :PM30 30KVA power module :35KG
Dimendion(W XD XH)mm  5 module cabinet  600X1400X850
10 module cabinet  600X2070X850
 power module 440X132X660(10KVA/20KVA/30KVA)

 

Please feel free to contact us, your inquiry will be replied within 24 hours.

 

SEO Article – Modular UPS syestems reliability analysis

Assessment of the reliability of the modular ups systems to perform their duties, not only to consider the MTBF UPS, but also to consider the MTTR UPS and the city of MTBF. When modular ups systems fails, the load will lose power, that is, the failure of the UPS’s key responsibilities. The length of time that the load is exposed to without protection depends on the length of the maintenance time. If a UPS maintenance for a week, and city power average without Jang time is for a week, then modular ups systems failure load will probably lose power. If the MTTR UPS is 1 hours, then the city’s MTBF will not have a significant impact on the failure probability of the critical load. It is clear that lowering the MTTR of the modular ups systems will reduce the failure probability of the critical load. The best way to reduce the MTTR of UPS is to minimize the factors that may affect the maintenance of UPS. Modular stand-alone UPS because of the function of online hot plug, the best choice is natural.
From the principle of design, take the whole power system of power supply must with highly fault-tolerant redundant power supply scheme, to ensure that no matter is out in the city power grid fault or in any module (including system control module) faults, is in for routine maintenance / maintenance operation or for some reason causing the fuse burned / circuit breaker trip and interconnection equipment shall be On-line UPS inverter power supply, and should not be entered by ordinary municipal power / emergency standby generator sets the ups AC side road to power of the state.
To sum up, stand alone modular ups systems have the longest duties mean failure time (lambda mission, minimum mean time to repair (MTTR) and the strongest anti City electrical interference risk ability and a high degree of fault tolerance function is most reliable power guarantee.

MPS9335C 30-300KVA With Switch Cabinet Modular UPS Systems