SEO Blog

076月 2017

When choosing solar inverters, first of all, should be paid attention to the identification of the packages and products, and to identify the input voltage range, voltage type and maximum input current of the solar inverter; Output voltage level, voltage type, frequency; Maximum continuous operating current, maximum output power, and inverting efficiency. Secondly, the data should be complete, should include at least the following: product details (including technical specifications), product installation instructions, instructions and maintenance instructions.

Solar panel inverter products as a general industrial products, it is recommended that professional personnel guide the use of professional and technical personnel. Non professional person purchased the products, should read product brochures and other documents carefully and strictly in accordance with the documentation requirements of installation, need to contact the manufacturer when in doubt, ensure the correct installation and use.

If purchase imported products, should pay attention to whether the statement is suitable for domestic standards, especially should pay attention to the output voltage and frequency of foreign products is matched to access to the domestic public power grid. In addition, also need to pay attention to that there are obvious differences between domestic and foreign standards for the over voltage protection and other requirements, when use the foreign products, there may be security risks, not recommended for non professionals to buy imported products.

For the professional purchase of solar power inverters, in addition to the maximum conversion efficiency marked on the nameplate, the MPPT is also need pay attention to, and the power quality during operation in low power (50% rated output power and below) , and the over / under voltage protection parameters. And according to different use environment to buy and use, such as: Household products should pay attention to electromagnetic compatibility and noise; Conventional products are suitable for installations where the elevation is not more than 1000m. The products used in high altitude areas need to lower the capacity; The temperature range of conventional products for the -25℃~+60℃, the use of extremely low temperature and high temperature area of the product should pay attention to the climate adaptability, for normal use with sufficient safety margin.

 

IG3115CT 1-6KW Pure Sinewave Inverter (1000w pure sine inverter,1000w inverter pure sine wave,pure sine wave inverter 1000w)

1. Pure Sine wave Output
2. The charging current is big up to 70 A
3. Output Power Factor is 0.9-1
4. Auto change AC-DC
5. Full automatic and silent operation
6. Automatically transfer between battery and line modes
7. Microprocessor control guarantees high reliability
8. Remote control function
9. Four-steps intelligent charging control to recharging time
10. Bypass and bypass voltage regulation function
11. Could be setting frequency by LCD display for 50hz or 60hz

Learn More

 

IG3115CT 1-6KW Pure Sinewave Inverter (1000w pure sine inverter,1000w inverter pure sine wave,pure sine wave inverter 1000w)

[contact-form-7 id="4336" title="联系表单 1"]

076月 2017

The rapid development of telecom technology, great changes have taken place in the internal and external environment of the telecom industry, as the basis of data center, UPS ushered in opportunities in cloud computing, virtualization, big data, cloud storage and other aspects. With the continuous expansion of data telecom network and the completion of various service, the technical transformation of power supply and the improvement of power supply maintenance have become the focus of telecom industry. In the telecom network, the higher the scale, the higher the grade, the more critical the business, the higher the requirement of the power supply quality. For example, the operators of the international data center (IDC), large telecom station, this kind of computer room is often required to obtain 365 days 24 hours of uninterrupted and stable, pure power, so it must be used with high reliability and high availability online UPS system. If the telecom network failure due to power problems, even if only a minute, can also caused loss of economic and corporate reputation. Therefore, the business nature of the telecom industry determines its high demand for power supply.

In addition, in order to save the operation and maintenance and energy costs, operators must also pay great attention to the level of data center UPS intelligent control, maintainability, energy efficiency and other aspects of performance. At present, the top three Chinese operators in order to fully protect the quality of the network, are strictly control the construction of the computer room. Environmental protection, energy saving, high efficiency and intelligence become the requirements of the new generation telecom data center for UPS.

 

HP9116C Plus 1-3KVA Online High Frequency UPS

 

1.Battery voltage can be choice depend on capacity , can satisfy different requirement.
2.Convenience to get more back up time and lower system invests
3.Convenience to save cost of battery
4.Intelligent battery monitors
Charge current can be adjust
5.Standant charge current 4A
6.Support more discharge time and more capacity battery for 8A charger
Input topology design
7.Support three phase input or single phase input for three phase online high frequency UPS
8.Super wide input voltage and frequency range suitable for bad power electirc environment
9.Digital control DSP technology and best power component make the system safe and reliable

Learn More

HP9116C Plus 1-3KVA Online High Frequency UPS

016月 2017

In addition to the cooling fan and circuit breaker switch components, there are a large number of solid state electronic devices in the UPS. They basically do not have mechanical wear, so they can work in the best running condition for a long time. It is necessary to find out the signs of trouble and prevent the hidden trouble from expanding, we must make the UPS work in a suitable environment and do routine maintenance. The working environment of UPS should be the same as that of the computer. The temperature should be controlled above 5 degrees Celsius and below 22 centigrade. The relative humidity should be controlled below 50%, and fluctuation range not exceeding 10%. Of course, it is equally important to these factors that keep the UPS workshop clean, dust-free, unpolluted, and harmful, as these factors also affect the service life of the UPS and cause trouble.

In the UPS daily maintenance work, engineers need daily routine inspection, its main purpose is to run the accumulated experience of online uninterruptible power supply and timely detection of fault signs, so the daily routine inspection should be careful.

 

GP9335C 10-800KVA Low Frequency Online UPS (120 kva UPS,double conversion online UPS)

■Use advanced 6th generation DSP and full digital control technologies to realize higher system stability.
■Output power factor is 0.9, carrying capacity than conventional 120 kva UPS with 10% above, as users reduce investment cost.
■Advanced distributed active parallel technology can realize parallel operation of 6PCS 120 kva UPS units without the need of centralized bypass cabinet.
■6-inch extra large LCD that can display 12 language ( Chinese ,English,Russian,Spanish,French and so on).
■Extra wide input voltage and frequency range make it adapt to severe power grid environment.
■Intelligent battery management maintains battery automatically to prolong the battery life.
■Standard input/output filter improves the system EMC performance.
■Extra strong capability to withstand output overload and short circuit, ensuring the system stability and system safety under extreme conditions.
■Layered independently-sealed ventilation channel and re-dundant fan, circuit boards with protective paints and a dust filter embedded make it highly efficient to dissipate heat and protect the product effectively under severeenvironment.

GP9335C 120-800KVA Low Frequency Online UPS (120 kva ups,double conversion online ups)

016月 2017

Hybrid solar inverter mainly has the function of solar on and off grid power generation, that is to say, in the case of normal power supply, the device closes the bypass relay to realize the power supply load on the household electrical appliance; When the power supply of the power network is not normal (such as the power grid is off, the power grid voltage or frequency fluctuation is relatively large), the device can carry out the power supply for the household electrical appliance after inverting through the battery. Under the condition of suitable sunshine intensity, the device can also be connected to the grid and sold to the grid to gain benefit when the solar power generation function is normal.

In terms of technical implementation, the device consists of the following units:
First is the inverter unit, the unit receive from solar power from solar panels and DC bus box, through the maximum power point tracking circuit, stable DC bus voltage, finally into the public power grid power generation by the inverter unit.
Second is the off grid solar inverter unit, when power supply is normal, through the bypass relay to the load power supply, at the same time to charge the batteries; when the power grid is out of order, through the inverter load to achieve uninterrupted power supply. At this time, if the PV module generates electricity, can be supplied to the load through the solar power inverter, and the battery is charged simultaneously.
Third is a switching unit, when the unit is in suitable light condition and the power grid is abnormal, supply power to the load through switching relays and other devices.
Fourth is the other auxiliary units, such as isolation unit, storage battery management unit, etc., used to achieve the management of storage battery, into the network, meters, network meters, solar panels and so on.

In general, the solar hybrid inverter can effectively overcome the existing problem of solar inverter is only suitable for grid connected generation, and when off grid inverter in the weak sun light, the electricity load is limit, can effectively improve the utilization efficiency of solar energy, especially suitable for power grid power supply is not stable or high cost.

 

SSP3119C 1-5KVA On/off Grid Hybrid Solar Inverter with Energy Storage

■Pure sine wave output
■Self-consumption and Feed-in to the grid
■Programmable supply priority for PV, Battery or Grid
■User-adjustable charging current and voltage
■Monitoring software for real-time status display and control
■Parallel operation up to 6 units only for 3K/4K/5K models
■Programmable multiple operation modes: Grid-tie,off-grid and grid-tie with backup

245月 2017

Grid connected solar inverters generally have 5~10 years of service life, and if it is used and maintained improperly, will seriously shorten the life of solar grid connected inverter, and even bring security risks.

First of all, according to usage requirements, need to determine the technical parameters of product, and then installed by professional technicians, and after approved by the local power sector, before the product can be connected into the power grid, put into use.

The input and output terminals for daily use need to regularly check the product is connected firmly, input and output cable whether aging or damaged skin scratch, grounding wire is strong, whether there is a break or fall off, should be found for professional replacement. Do not arbitrarily remove the input and output terminals and their protective cover. Should avoide exposure of the live metal parts of the input and output terminals.

When daily use, as the inverter fails, the connection protection switch for the power grid shall be disconnected immediately, and the inverter can be turned on again after the professional has been removed from the power grid.

The maintenance of the product to should be operated by technical personnel, before any maintenance work, should firstly disconnect the grid connected solar system inverter, then disconnect the DC electrical connection, wait at least 5 minutes until the internal components of discharge is completed before the repair work.

Non professionals should not disassemble the product shell, when professional personnel in maintenance, shall comply with the warning signs, should wear anti-static gloves, to avoid unnecessary contact with the circuit board, also note that exposed hands do not touch the inverter’s power devices and heat abstractor directly, after a period of time, there are still high temperature.

In the daily use, the product should be in a good ventilation environment. It can clean the product surface and the air inlet and outlet dust with a clean and soft dry cloth regularly, and keep the good heat dissipation of the product.

 

SSP3119C 1-5KVA On/off Grid Hybrid Solar Inverter with Energy Storage

■Pure sine wave output
■Self-consumption and Feed-in to the grid
■Programmable supply priority for PV, Battery or Grid
■User-adjustable charging current and voltage
■Monitoring software for real-time status display and control
■Parallel operation up to 6 units only for 3K/4K/5K models
■Programmable multiple operation modes: Grid-tie,off-grid and grid-tie with backup
On Off Grid Hybrid Solar Power Inverter with battery pack,high frequency pure sine wave output, PF.=1.0, parallel working Max 6units(30KW) – SSP3119C 1-5KVA

SSP3119C 1-5KVA Onoff Grid Hybrid Solar Inverter with Energy Storage