Home

244月 2018

1.Before using the power supply, make sure whether the input and output voltage specifications are consistent with the nominal values of the power supply.
2.Before electrifying, check if the input and output leads are connected correctly, so as not to damage user equipment.
3.Check whether the installation is solid, whether there is contact between the installation screws and the power supply devices, and measure the insulation resistance of the housing and input and output, so as to avoid electric shock.
4.In order to ensure safety and reduce interference, ensure that the grounding terminal is reliably grounded.
5.The output power is usually divided into main and auxiliary output, and the main output characteristic is superior to the auxiliary output. In general, the output current is large and the output is mainly. In order to guarantee the output load adjustment rate and output dynamic performance, it is generally required to carry at least 10% load per route. If the auxiliary road does not use the main road, the main road must add proper false loads. Refer to the specification of the corresponding model.
6.Please note that power frequent switch will affect its life.
7.The working environment and the degree of load will also affect their life.

 

SOROTEC SP6U-48200 48V Switching Power Supply Embedded System

1.Constructed with standard 19 inch screen, which has the advantage of wide use.
2.The data center area and the installation cost can be saved due to its small size and the embedded installation.
3.Wide input voltage range (85-290Vac), the power grid is adaptable.
4.Perfect lightning protection.
5.Rectifiers are hot-pluggable. Easy and quick on line maintenance.
6.The rectifier uses DSP (Digital Signaling Processor) ology, makes the power density ran up to 14W/In3.
7.Battery management, prolongs the life of the battery well.
8.Have passed CE, UL, TLC, and other related certifications.
9.Excellent energy conservation and environmental protection.

Learn More

164月 2018

Low temperature will bring changes in physical properties of electronic components, and this change tends to be in an unfavorable direction. Blizzard has a great impact on photovoltaic power stations. Too thick snow will lead to over icing of components, affecting the power generation and life of the system, resulting in a decline in power generation and even stop work. For solar inverter, it is a severe test. Cold climate conditions may make the inverter can not work steadily, such as can not start, frequent alarm, power generation reduction and other problems.

 

How to choose inverter to deal with the erosion of extreme weather?

1.Select components of wide range of working temperature to fully meet the low temperature service conditions.
2.Takes full account of the demand for low temperature work in the design of the product, leaving enough margin (including capacity margin and time margin).
3.The product should be tested for a long time at low temperature to ensure the validation of theoretical value.

 

How to do the inspection of the outdoor inverter well?

After long time use, there will be aging phenomenon in the connection of inverter.The inverter has its own insulation impedance detection, which can reliably protect the inverter. At the same time, it needs to pass the on-site inspection, and the thermal imager can scan the connection points of each cable at work; Check whether the inverter PV input terminal is stable or loose; Whether the AC terminal is aging and loosening; Whether there is grounding in the PV line under the sun plate.

 

REVO-II On/Off Gird Energy Storage Hybrid Inverter with Touch Screen

1.Touch screen display.
2.Output power factor PF=1.0.
3.On + Off Grid with energy storage.
4.Energy generated record, load record, history information and fault record.
5.Connected with battery optional.
6.Wide PV Input Range.

Learn More

hybrid off grid inverter,hybrid off grid solar inverter,on grid off grid hybrid inverter

164月 2018

The leakage current of the solar power system, also known as the square array residual current, is essentially common mode current, which is caused by the existence of parasitic capacitance between the solar power system and the earth. When the parasitic capacitance, and solar power system and the power grid forms a loop, the common mode voltage will produce common mode current on the parasitic capacitance. When the low frequency transformer is installed in the solar power system, the parasitic capacitance impedance of the transformer windings in the loop is relatively large, so the common mode current produced by the loop voltage of the CCP can be restrained. However, in a solar power system without transformer, the circuit impedance is relatively small, and the common mode voltage will form a larger common mode current on the parasitic capacitance between the solar power system and the earth, that is, leakage current.

The leakage current in the solar power system includes the DC and AC parts. If connect to the grid, the problems of the grid current distortion and electromagnetic interference will be caused, which will affect the operation of the equipment in the power grid. Leakage current may also cause the solar inverter enclosure to be electrified, which will pose a threat to personal safety.

 

SPS3115C Series 1-10KVA Outdoor Solar Power system

1.Pure sine wave inverter
2.Built-in MPPT solar charge controller
3.Could be built-in battery
4.Protection degree:IP55
5.Configurable input voltage range for home appliances and personal computers via LCD setting
6.Configurable AC/Solar Charger priority via LCD setting
7.Compatible to mains voltage or generator power
8.Auto restart while AC is recovering
9.Overload/Over temperature/short circuit protection
10.Configurable battery charging current based on applications via LCD setting

Learn More

SPS3115C Series 1-10KVA Outdoor Solar Power system(Outdoor solar power system,outdoor solar system,solar off grid system) 1

094月 2018

The leakage current of the solar power system is essentially common mode current, which is caused by the existence of parasitic capacitance between the photovoltaic system and the earth. When the parasitic capacitance – photovoltaic system – power grid three forms a loop, the common mode voltage will produce common mode current on the parasitic capacitance. When the power frequency transformer is installed in the photovoltaic system, the parasitic capacitance impedance of the transformer windings in the loop is relatively large, so the common mode current produced by the loop voltage of the CCP can be restrained. However, in a photovoltaic system without transformer, the circuit impedance is relatively small, and the common mode voltage will form a larger common mode current on the parasitic capacitance between the photovoltaic system and the earth, that is, leakage current.

The leakage current in the photovoltaic system includes the DC and AC parts. If the grid is connected to the grid, the problems of the grid current distortion and electromagnetic interference will be caused, which will affect the operation of the equipment in the power grid. Leakage current may also cause the inverter housing to be electrified, which will pose a threat to personal safety.

 

SSP3111C 1-2KVA High frequency Modified Sine Wave Off-grid Solar Power Inverter

1.Built-in PWM solar charge controller.
2.Modified sine wave output.
3.High frequency design.
4.Optional input voltage range.
5.Full automatic and silent operation.
6.Automatic charging.
7.Auto change AC-DC.
8.Over-load protection.
9.Automatic restart.
10.Three-steps intelligent charging control to recharging.
11.LCD display, audible and visual alarm.
12.Mains/solar output priority level for the customer to choose .
13.Mains/solar/ mains & solar charging three mode of prioritiesfor the customer to choose.
14.Built-in with 10 or 20 Amp charger for up to 200Ah battery.

Learn More

SSP3111C 1-2KVA Modified Sine Wave Solar Power Inverter For Home With PWM Solar Charge Controller 1

 

094月 2018

The power supply system belongs to the airport public equipment, and the public equipment space of the airport terminal is limited. For the airport construction department, centralized power supply system needs to minimize the occupancy space under the premise of ensuring reliability. The traditional large capacity tower type UPS occupies a large space, and occupies more than twice the space occupied by modular UPS. If the 2N system is adopted, the space will be larger, and the space of the battery should be added, which is not suitable for the airport.

Therefore, considering the comprehensive consideration of airport construction department, modular UPS should be selected. The same capacity occupies almost half of the traditional tower UPS. At the same time, the active devices such as modular UPS power module, bypass module, control module and other active devices are all designed by hot plug. The system can meet the requirements of the airport to the reliability of the UPS by using the N+X architecture. It not only saves space for occupying space, but also facilitates operation and maintenance.

Once the traditional tower type UPS fails, it is necessary for the technical personnel of the original factory to carry out the maintenance. The maintenance time is often more than 24 hours. If the maintenance period is out of date, it is more unable to guarantee the availability. While modular UPS, only need to pass the spare parts power module, once the power module failure, the airport mechanical and electrical departments can be repaired, the failure module to move out, spare parts module into the line and everything can be done.

 

MPS9335C 10-1200KVA With Switch Cabinet Modular UPS Systems

1.Superior energy saving and environment-friendly: Efficiency > 96% at 50%-75% rated load, and > 95% at 25% rated load; Input PF > 0.99,input THDi<3%.
2.Superior capability of powering load: Output PF is 0.9 or 1, no need of power deration with load of leading or lagging PF.
3.Easy-to-install: Top or bottom cabling, no need of input cabling cabinet.
4.Easy-to-maintain: Full front access, UPS, failed part can be replaced shortly.
5.Easy-to-modify: The number of battery cells can be configured flexibly, so the original batteries can be used when modifying the legacy system; moreover, the battery cell can be replaced in time when it fails without interrupting the normal operation of modular ups systems.
6.6-inch extra large LCD that can display 13 language (Chinese ,English ,Russian, French ,Spanlish and so on).
7.Provide large LCD touch screen (optional).
8.Each UPS modules provide 4.5KW charge capacity. equivalent to 10 to 12A.
9.On-Line Double Conversion, fully isolating the influences of power grid pollution and power failure from utility power supply and diesel generator to load.
10.Advanced DSP full digital control technologies realize higher system stability, online capacity expansion and maintenance.
11.Advanced distributed active parallel technology realizes parallel operation of 4 UPS units and online capacity expansion without centralized bypass cabinet.
12.Digital load sharing technology features extra low cross current and extreme high system reliability in parallel operation.
13.Adaptive to severe power grid environment due to extra wide input voltage and frequency ranges.
14.Extra strong capability to withstand output overload and short circuit, ensuring the system stability and system safety at limit conditions.
15.Intelligent battery management maintains battery automatically to prolong the battery life.
16.Efficient heat dissipation and effective protection under severe environment due to its independent layer-sealed ventilation channel and redundant fan design, as well as the paint-protected circuit boards and built-in dust filter.
17.Applicable voltage south America.

Learn More

MPS9335C 10-1200KVA With Switch Cabinet Modular UPS Systems