SEO Blog

098月 2017

The leakage current is the current flowing into the ground through the earth conductor. In ungrounded situations, if there is a conductive path (such as human body), the current may flow from the surface of the conductive component or the non-conductive part to the ground. An external current is always present in the safety grounding conductor. Usually, the upper limit of the leakage current of medical power is 1/10 of the common power supply.

All power leakage current indicators of the IEC601 standard are far more stringent than non medical power supplies. The technical specifications define several different and critical leakage currents, such as the drain current (along the ground into the ground) and the leakage current of the casing. In the IEC601 standard, the maximum leakage current of the medical power supply of the three main types of equipment is defined differently:
Class B: equipment that is not in contact with the patient, such as a laser therapy apparatus.
Class BF: equipment that need to contact the patient, such as ultrasound, various monitors (including EGC equipment), and operating table.
Class CF: equipment to contact the patient’s heart, such as a cardiac puncture monitor.

It is often misunderstood that leakage current indicators are different for these devices. In fact, the leakage currents allowed for these devices are the same. The North American index requires more stringent leakage currents than the European EN60601-1 provides. Europe, for example, allows 0.5mA, while the United States and Canada allow only 0.3mA. As a result, medical device designers need to be aware of where their products will be sold.

And BF or CF devices (commonly known as “contact with the body” equipment) also require additional insulation measures to enable the patient and the ground, signal port and power output insulation. This is to protect the patient from accidental failures of the equipment and to keep the leakage current within the standard limits. This insulation can also be achieved through other parts of the final equipment, such as plastic probes or bushings with sufficient insulation. But in the case of the need to electrify the patient, one of the treatment methods is to use the DC/DC power supply according to the IEC601-1 standard to supply power to add second level insulation protection. Therefore, the DC/DC converter must be carefully selected to ensure that the insulation requirements are met.

 

SOROTEC GP9335C 10-800KVA Low Frequency Online UPS for hospital

■Use advanced 6th generation DSP and full digital control technologies to realize higher system stability.
■Output power factor is 0.9, carrying capacity than conventional 120 kva UPS with 10% above, as users reduce investment cost.
■Advanced distributed active parallel technology can realize parallel operation of 6PCS 120 kva UPS units without the need of centralized bypass cabinet.
■6-inch extra large LCD that can display 12 language ( Chinese ,English,Russian,Spanish,French and so on).
■Extra wide input voltage and frequency range make it adapt to severe power grid environment.
■Intelligent battery management maintains battery automatically to prolong the battery life.
■Standard input/output filter improves the system EMC performance.
■Extra strong capability to withstand output overload and short circuit, ensuring the system stability and system safety under extreme conditions.
■Layered independently-sealed ventilation channel and re-dundant fan, circuit boards with protective paints and a dust filter embedded make it highly efficient to dissipate heat and protect the product effectively under severeenvironment.

Learn More

GP9335C 120-800KVA Low Frequency Online UPS (120 kva ups,double conversion online ups)

048月 2017

Telecom power is the key infrastructure of the entire telecom network, but the proportion of telecom power in the entire telecom industry is not high. Telecom operators purchase in the power supply products is mainly the annual equipment maintenance and system equipment. Among them, the maintenance of power supply equipment usually accounts for a higher proportion of procurement. Telecom operators spend relatively little money on building power systems each year, unless carriers need large-scale upgrades or expansions, operators will increase the amount of power equipment purchases.

The telecom power supply system is the heart of the telecom system, stable and reliable power supply system, communication system is the key to ensure the safe and reliable operation of telecom system, once the fault caused by the telecom power supply system for telecom equipment interruption, telecom equipment will not run, resulting in economic and social benefits cadmean. Therefore, the telecom power supply system occupies a very important position in the telecom system.

The growth in damand of the telecom power market is limited, but from a more long-term development trend analysis, telecom power supply in the next 2 years will usher in a small climax.

For telecom power supply, buyers are not limited to telecom operators, as well as telecom equipment manufacturers, this huge market. Whether for telecom operators, or equipment research and development, processing and assembly manufacturing enterprises, it can not be ignored. China is a famous manufacturing base in the world, and this has objectively created a strong market pillar for power supply products. These will undoubtedly help the telecom power industry successfully smoothly through the market winter.

 

SOROTEC SP6U-48200 48V Telecom Power Supply Embedded System

AC Input:

Rated input voltage :220V
AC input Voltage range:90-290V
AC input Frequency range:43-67HZ
Power factor :≥0.99
Efficiency : >92%

 

DC output :

■ Rated voltage: 48V switching power supply
■ Voltage range: 42-58V
■ Rated Current: 200A
■ load Distribution: 4 outlet load
■ battery Distribution: 2 outlet battery
■ battery LVD:100A×2
■ Mode of connection: connect terminal to front panel
■ Rectifier Module: SR4850
■ Monitoring Module: STM-11

 

Input —-output 3000Vac/10mA//1min No arcing, no breakdown
Input—- chassis 2500Vac/10mA//1min No arcing, no breakdown
Input—- chassis 500Vac/10mA//1min No arcing, no breakdown

 

Operating temperature -40 ~+70°c
Humidity : 95% non-condensing

 

Dimensions(W H D): 480 270 300(mm)
Weight(Kg): 20kg (include rectifier module)

Learn More

297月 2017

The power used in medical CT machine, X-ray apparatus are relatively large, once the power off require a longer backup time. General Electric preparation industry standard is 2 hours long, but SOROTEC suggested that, for better operational experience and prevent the city power outage time is too long, the backup time of CT machine is preferably over 4 hours. As for the model, because the hospital uses a variety of medical equipment, and the general power is relatively large, which led to fluctuations in the frequency, the electricity environment is bad. Therefore, for medical equipment needs to develop a special UPS power supply, requiring its stability, high power, high efficiency, small space occupation and so on. The default of medical UPS is no batteries, customers can choose their own battery, you can also request the uninterruptible power supply company to configure. 120KVA medical grade UPS power supply can be applied to large power CT machine, which backup time ≥4 hours, is suitable for large hospital.

SOROTEC HP9335C Plus 10-30KVA High Frequency Intelligent UPS

1.True double-conversion
2.DSP technology guarantees high performance
3.Output power factor 0.9
4.Wide input voltage range (110-300 VAC)
5.Active power factor correction in all phases
6.50Hz/60Hz frequency converter mode
7.ECO mode operation for energy saving
8.Accepts dual-mains inputs
9.Emergency power off function (EPO)
10.Generator compatible
11.SNMP+USB+RS-232 multiple communications
12.3-stage extendable charging design for optimized battery performance
13.Adjustable battery numbers
14.Maintenance bypass available
15.Optional N+X parallel redundancy
16.Optional isolation transformer offers full isolation and complete common mode noise rejection

Learn More

HP9335C Plus 10-30KVA High Frequency Intelligent UPS

287月 2017

In the all centralized mode, the computer system is composed of computer and network and other electronic equipment. These electronic equipments have strict technical standards and requirements for the power system. UPS power supply system, usually refers to the UPS host, storage battery, static bypass switch and other auxiliary equipment, in order to realize the network data center run 365 days, 24 hours continuously,  can not achieve by only relying on the UPS which is high working efficiency and output ability, the input and output power distribution cabinets, circuit breakers, switches and transmission cables in the data center UPS system are choke points of failure, if there is a problem, it will inevitably lead to system outages.Therefore, to achieve near zero fault power supply, it must be a redundant power supply system with high fault tolerance. They are generally composed of 2/multiple way city power supply redundancy power system + standby generator + 1/multiple automatic transfer switch + anti lightning transient surge suppressor and IDC UPS power supply system. This is basically a distribution system which will never be a power failure, the maintenance and repair operation of “no power interruption” is allowed, can increase its availability to 99.999%, network room down time less than 5.26 minutes per year.

 

SOROTEC HP9116C Plus 1-3KVA Online High Frequency UPS

Application: Data center, bank station, network , telecom station, office, automatic equipment,monitor equipment, control system

Learn More

HP9116C Plus 1-3KVA Online High Frequency UPS

227月 2017

The advantage of decentralized bypass is that bypass redundancy is claimed, the centralized bypass is considered to be a single fault point.

(1)From the point of view of type selection
From the point of view of device selection, the modular UPS system reliability of single high power SCR is much higher than small devices consisting of a centralized bypass, which function module is simple, only need to consider the influence of the device and a few peripheral driving circuit, while the decentralized bypass is distributed in the power module, but also affected by many internal device module. Engineers who have experience in maintenance all know that, faults of rectifier and inverter circuit are likely to be caused by other parts of the circuit because of sparks and spatter, that is to say the static bypass facing more uncertainty risk. If the bypass is a single fault, the bypass may be referred to as a multiple point fault.

(2)From the point of view of system capacity
From the point of view of system capacity, the capacity of centralized bypass is designed according to the cabinet, irrespective of the number of modules configured. The static bypass capacity of the decentralized bypass is determined by the module capacity, that is, when the module fails, the system will lose the corresponding static bypass capacity. The same condition is not a problem for centralized bypass. Because of the advantages of the capacity and even the ability of some manufacturers to provide 125% long-term overload, the centralized bypass module has absolute guarantee for system reliability.

(3)Reliability design analysis of centralized bypass
The reliability design of centralized bypass, many manufacturers have put forward many solutions to enhance the reliability, such as redundancy control circuit scheme, redundant communication bus scheme, power module and control module bypass decoupling scheme, power module in the bypass control scheme, the solution of each of the manufacturers have their own characteristics, can greatly to enhance the usability of the system, plus the common hot swappable bypass module design, maintenance and upgrade is as simple as the power module.

 

SOROTEC MPS9335 30-150KVA Modular UPS

1.Superior energy saving and environment-friendly: Efficiency > 96% at 50%-75% rated load, and > 95% at 25% rated load; Input PF > 0.99,input THDi<3%.
2.Superior capability of powering load: Output PF is 0.9 or 1, no need of power deration with load of leading or lagging PF.
3.Easy-to-install: Top or bottom cabling, no need of input cabling cabinet.
4.Easy-to-maintain: Full front access, UPS, failed part can be replaced shortly.
5.Easy-to-modify: The number of battery cells can be configured flexibly, so the original batteries can be used when modifying the legacy system; moreover, the battery cell can be replaced in time when it fails without interrupting the normal operation of UPS.
6.6-inch extra large LCD that can display 12 language (Chinese ,English ,Russian, French ,Spanlish and so on).
7.Provide large LCD touch screen (optional).
8.Each UPS modules provide 4.5KW charge capacity. equivalent to 10 to 12A.
9.On-Line Double Conversion, fully isolating the influences of power grid pollution and power failure from utility power supply and diesel generator to load.
10.Advanced DSP full digital control technologies realize higher system stability, online capacity expansion and maintenance.
11.Advanced distributed active parallel technology realizes parallel operation of 4 UPS units and online capacity expansion without centralized bypass cabinet.
12.Digital load sharing technology features extra low cross current and extreme high system reliability in parallel operation.
13.Adaptive to severe power grid environment due to extra wide input voltage and frequency ranges.
14.Extra strong capability to withstand output overload and short circuit, ensuring the system stability and system safety at limit conditions.
15.Intelligent battery management maintains battery automatically to prolong the battery life.
16.Efficient heat dissipation and effective protection under severe environment due to its independent layer-sealed ventilation.
channel and redundant fan design, as well as the paint-protected circuit boards and built-in dust filter.
17.Applicable voltage south America.

Learn More about SORTEC modular power solutions